LTC1415
APPLICATIONS INFORMATION
WU
U
CONVERSION DETAILS
The LTC1415 uses a successive approximation algorithm
and an internal sample-and-hold circuit to convert an
analog signal to a 12-bit parallel output. The ADC is
complete with a precision reference and an internal clock.
The control logic provides easy interface to microproces-
sors and DSPs (please refer to Digital Interface section for
the data format).
Conversion start is controlled by the CS and CONVST
inputs. At the start of the conversion the successive
approximation register (SAR) is reset. Once a conversion
cycle has begun it cannot be restarted.
During the conversion, the internal differential 12-bit
capacitive DAC output is sequenced by the SAR from the
most significant bit (MSB) to the least significant bit (LSB).
Referring to Figure 1, the +AIN and –AIN inputs are con-
nected to the sample-and-hold capacitors (CSAMPLE) dur-
ing the acquire phase and the comparator offset is nulled by
the zeroing switches. In this acquire phase, a minimum
delay of 150ns will provide enough time for the sample-
and-hold capacitors to acquire the analog signal. During
the convert phase the comparator zeroing switches open,
putting the comparator into compare mode. The input
switches the connect CSAMPLE capacitors to ground, trans-
ferring the differential analog input charge onto the sum-
ming junction. This input charge is successively compared
with the binary weighted charges supplied by the differen-
tial capacitive DAC. Bit decisions are made by the high
speed comparator. At the end of a conversion, the differ-
ential DAC output balances the + AIN and – AIN input
charges. The SAR contents (a 12-bit data word) which
represents the difference of + AIN and –AIN are loaded into
the 12-bit output latches.
DYNAMIC PERFORMANCE
The LTC1415 has excellent high speed sampling capabil-
ity. FFT (Fast Fourier Transform) test techniques are used
to test the ADC’s frequency response, distortion and noise
at the rated throughput. By applying a low distortion sine
wave and analyzing the digital output using a FFT algo-
rithm, the ADC’s spectral content can be examined for
frequencies outside the fundamental. Figure 2 shows a
typical LTC1415 FFT plot.
Figure 1. Simplified Block Diagram
COMP
+CSAMPLE
–CDAC
D11
D0
ZEROING SWITCHES
HOLD
+AIN
–AIN
+CDAC
–CSAMPLE
12
LTC1415 F01
+
SAR
OUTPUT
LATCHES
+VDAC
–VDAC
HOLD
SAMPLE
FREQUENCY (kHz)
0
AMPLITUDE
(dB)
0
–20
–40
–60
–80
–100
–120
100
200
300
400
LTC1415 F02
500
600
fSAMPLE = 1.25MHz
fIN = 99.792kHz
SFDR - 87.5
SINAD = 72.1
Figure 2. LTC1415 Nonaveraged, 4096 Point FFT
Signal-to-Noise Ratio
The signal-to-noise plus distortion ratio [S/(N + D)] or
SINAD is the ratio between the RMS amplitude of the
fundamental input frequency to the RMS amplitude of all
other frequency components at the A/D output. The output
is band limited to frequencies from above DC and below
half the sampling frequency. Figure 2 shows a typical
spectral content with a 1.25MHz sampling rate and a
100kHz input. The dynamic performance is excellent for
input frequencies up to the Nyquist limit of 625kHz.
相关PDF资料
LTC1416IG#TR IC ADC 14BIT 400KSPS SMPL 28SSOP
LTC1417AIGN#TR IC ADC 14BIT 400KSPS SMPL 16SSOP
LTC1418ACG#TRPBF IC A/D CONV 14BIT SRL&PAR 28SSOP
LTC1419AISW#TRPBF IC A/D CONV 14BIT SAMPLNG 28SOIC
LTC1420IGN#TRPBF IC ADC 12BIT 10MSPS SAMPL 28SSOP
LTC1426IS8#TR IC DAC PWM 6BIT DUAL MCPWR 8SOIC
LTC1427CS8-50#TRPBF IC D/A CONV 10BIT W/SMBUS 8-SOIC
LTC1428CS8-50#TRPBF IC D/A CONV 8BIT SINK OUT 8-SOIC
相关代理商/技术参数
LTC1415CSW 功能描述:IC A/D CONV 12BIT SAMPLNG 28SOIC RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
LTC1415CSW#PBF 功能描述:IC A/D CONV 12BIT SAMPLNG 28SOIC RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:microPOWER™ 位数:8 采样率(每秒):1M 数据接口:串行,SPI? 转换器数目:1 功率耗散(最大):- 电压电源:模拟和数字 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:24-VFQFN 裸露焊盘 供应商设备封装:24-VQFN 裸露焊盘(4x4) 包装:Digi-Reel® 输入数目和类型:8 个单端,单极 产品目录页面:892 (CN2011-ZH PDF) 其它名称:296-25851-6
LTC1415CSW#TR 功能描述:IC ADC 12BIT 1.25MSPS SMP 28SOIC RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
LTC1415CSW#TRPBF 功能描述:IC A/D CONV 12BIT SAMPLNG 28SOIC RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
LTC1415CSWPBF 制造商:Linear Technology 功能描述:LTC1415CSWPBF
LTC1415IG 功能描述:IC A/D CONV 12BIT SAMPLNG 28SSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极
LTC1415IG#PBF 功能描述:IC A/D CONV 12BIT SAMPLNG 28SSOP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1 系列:microPOWER™ 位数:8 采样率(每秒):1M 数据接口:串行,SPI? 转换器数目:1 功率耗散(最大):- 电压电源:模拟和数字 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:24-VFQFN 裸露焊盘 供应商设备封装:24-VQFN 裸露焊盘(4x4) 包装:Digi-Reel® 输入数目和类型:8 个单端,单极 产品目录页面:892 (CN2011-ZH PDF) 其它名称:296-25851-6
LTC1415IG#TR 功能描述:IC ADC 12BIT 1.25MSPS SMP 28SSOP RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 标准包装:1,000 系列:- 位数:12 采样率(每秒):300k 数据接口:并联 转换器数目:1 功率耗散(最大):75mW 电压电源:单电源 工作温度:0°C ~ 70°C 安装类型:表面贴装 封装/外壳:24-SOIC(0.295",7.50mm 宽) 供应商设备封装:24-SOIC 包装:带卷 (TR) 输入数目和类型:1 个单端,单极;1 个单端,双极